An overview of photometry applications, trends

13 May 2013  | Robert Burnham, Antoine Lourdes Praveen Aroul, Lijoy Philipose

Share this page with your friends

Pulse oximetry has been a crucial tool in helping to save lives and improving the quality of life for well over 50 years. Pulse oximeters monitor the oxygen saturation and heart rate of the wearer noninvasively. Advanced units are able to display the pulsatile nature of the arterial blood vessels. The pulse oximeter is an important medical tool that aids in the diagnosis of cardiac and vascular anomalies in neonatal, pediatric, and adult patients. Analysis of the pulsatile signal gives trained professionals a wealth of information about the respiratory, circulatory, and cardiovascular systems—all without taking a blood sample.

Pulse oximeters are also being used in the home. They are routinely used to determine home oxygen liter-flow and to monitor respiration and heart rate during exercise. Serious athletes and professional trainers monitor oxygen levels to optimise efficiency during strenuous workouts.

This year's Consumer Electronics Show (CES) in Las Vegas, United States witnessed many new heart rate monitor devices that are being made available to consumers. Many of these devices measure heart rate by acquiring the electrical activity of the heart, predominantly with a chest strap or wristwatch. Chest strap heart monitors have been around a long time, and they work well—but tend to be uncomfortable. The typical wrist-based heart rate monitors is bio-potential-based, and requires contact with both hands to take a measurement. The ideal device would be a passive, but continuously measuring vitals, including heart rate. The device needs to be comfortable to wear and positioned on the body in a location that does not interfere with daily activities. Ideal locations include the wrist, ears, forehead, forearm, calf, neck or ankle.


Figure 1: Oxygenated versus deoxygenated blood light absorption of IR and RED.


Principle of operation
The operating principle for a pulse-oximeter being used to measure the blood oxygen saturation level is to project light (normally LED) sources of different wavelengths through the body tissue to a photo-detector. Typically, the LED wavelengths being used for pulse-oximeters are red (~660 nm) and infrared (~905 nm). These two wavelengths of light, are absorbed by the blood at different rates, dependent upon the blood oxygen level.

When the blood is oxygenated red light is absorbed to a lesser extent than when using the infrared (IR) light. When the blood is deoxygenated, red light is absorbed to a greater extent than the IR light. This can be seen in figure 1, which shows light absorption by wavelength and whether the blood is oxygenated (HbO2) or de-oxygenated (Hb).

Common body locations for taking pulse-oximeter measurements are through the tissue at the fingertip, earlobe, or foot (normally on infants). LEDs intensity, tissue thickness, skin colour, sensor placement, and the oxygenated and deoxygenated blood light absorption all need to be considered during measurement.

The oximeter calculates oxygen saturation by taking the ratio of the absorption of red and infrared light, separating the time invariant parameters (intensity of light, skin colour, tissue type, and deoxygenated blood) from the time varying parameters (oxygenated blood). Normal oxygen saturation values for a healthy individual range between 95 and 100 per cent. The measured signal is pulsatile in nature due to the arterial blood vessels which expand and contract corresponding to each heartbeat. There are two types of pulse-oximeter measurements: transmissive and reflective. Reflective is normally used on the chest or forehead locations. Transmissive, which is more common, is normally used for finger, earlobe, or infant foot locations.

1 • 2 • 3 Next Page Last Page


Want to more of this to be delivered to you for FREE?

Subscribe to EDN Asia alerts and receive the latest design ideas and product news in your inbox.

Got to make sure you're not a robot. Please enter the code displayed on the right.

Time to activate your subscription - it's easy!

We have sent an activate request to your registerd e-email. Simply click on the link to activate your subscription.

We're doing this to protect your privacy and ensure you successfully receive your e-mail alerts.


Add New Comment
Visitor (To avoid code verification, simply login or register with us. It is fast and free!)
*Verify code:
Tech Impact

Regional Roundup
Control this smart glass with the blink of an eye
K-Glass 2 detects users' eye movements to point the cursor to recognise computer icons or objects in the Internet, and uses winks for commands. The researchers call this interface the "i-Mouse."

GlobalFoundries extends grants to Singapore students
ARM, Tencent Games team up to improve mobile gaming


News | Products | Design Features | Regional Roundup | Tech Impact